PS0200

The 50kVA heat treatment unit provides power to electrical resistance heaters (at 65v) which is split into 6 individual heating circuits to enable the individual temperature control of each circuit. There are 2 operational methods of heat control; an external programmer for all channels, and individual proportional energy regulators. Sufficient for 3 flexible ceramic pad heaters per channel, this mobile unit is suitable for both site or fabrication shop use.


Specification

  • Dimensions: 1110 H x 685 W x 695 D mm
  • Weight: 343kg
  • Primary: 415v
  • Secondary: 65v 270A per phase
  • Cooling: Natural Air Cooling
  • Insulation: Class H
  • Protection: MCB shunt trip
  • Contactors: 110v single pole, 180A
  • Manual set: 6 x energy regulators
  • Remote: 2 x 110v Aux sockets
  • Rating: 100% to 35°C